Motor Protection Switches


Order No.:
27H5216
Manufacturer SKU:
3RU2116-1EJ0
Order No.:
80P7177
Manufacturer SKU:
3RV1611-1AG14


Order No.:
81P0020
Manufacturer SKU:
3RV1011-0KA10
Order No.:
81P0100
Manufacturer SKU:
3RV2011-0JA20


Order No.:
81P0443
Manufacturer SKU:
3RV2111-0FA10


Order No.:
27H2644
Manufacturer SKU:
3RB3016-1NB0


Order No.:
27H2645
Manufacturer SKU:
3RB3016-1NE0
Order No.:
27H2646
Manufacturer SKU:
3RB3016-1PB0
Order No.:
27H2647
Manufacturer SKU:
3RB3016-1PE0


Order No.:
27H2648
Manufacturer SKU:
3RB3016-1RB0


Order No.:
27H2649
Manufacturer SKU:
3RB3016-1RE0
Order No.:
27H2650
Manufacturer SKU:
3RB3016-1SB0


Order No.:
27H2651
Manufacturer SKU:
3RB3016-1SE0
Order No.:
27H2652
Manufacturer SKU:
3RB3016-1TB0


Order No.:
27H2653
Manufacturer SKU:
3RB3016-1TE0


Order No.:
27H2654
Manufacturer SKU:
3RB3016-2NB0


Order No.:
27H2655
Manufacturer SKU:
3RB3016-2NE0
Order No.:
27H2656
Manufacturer SKU:
3RB3016-2PB0
Order No.:
27H2657
Manufacturer SKU:
3RB3016-2PE0


Order No.:
27H2658
Manufacturer SKU:
3RB3016-2RB0
Protect your electric motor effectively with a motor protection switch
The purpose of a motor protection switch (MSS) is to protect electric motors from overload. This can be a form of thermal overload caused by a mechanical overload. But it is also necessary to prevent non-starting or failure of external conductors with the help of a motor protection switch. Monitoring is therefore implemented thermo-mechanically, thermo-electrically or electronically.
Motor-protective circuit breakers are used, for example, with three-phase motors. They always have an overcurrent and a short-circuit current release device, and in some cases also an undervoltage release.
Buy motor protection switches - what to consider?
If you are looking for a suitable motor protection switch, it is important to take a close look at the electric motor to be connected. After all, the choice of the right motor-protective circuit breaker depends on the rated current of the motor. In addition, various standards may have to be observed. For example, if the motor-protective circuit-breaker is to provide overload protection and short-circuit protection for the cable and the motor. In this case, the motor protection switch must be installed at the beginning of the motor allocation in accordance with DIN VDE 0113.
Do you have questions about the motor protection switches in the Bürklin Elektronik online store? Or do you need detailed advice regarding the models shown? Don't hesitate and contact the Bürklin experts via telephone or e-mail! We are here for you and your questions.