Motor Protection Switches


Order No.:
02P7012
Manufacturer SKU:
GV4P12N


Order No.:
02P7013
Manufacturer SKU:
GV4P12N6


Order No.:
02P7014
Manufacturer SKU:
GV4P25B


Order No.:
02P7016
Manufacturer SKU:
GV4P25N


Order No.:
02P7017
Manufacturer SKU:
GV4P25N6


Order No.:
02P7018
Manufacturer SKU:
GV4P50B


Order No.:
02P7020
Manufacturer SKU:
GV4P50N


Order No.:
02P7021
Manufacturer SKU:
GV4P50N6


Order No.:
02P7022
Manufacturer SKU:
GV4P80B


Order No.:
02P7023
Manufacturer SKU:
GV4P80B6


Order No.:
02P7024
Manufacturer SKU:
GV4P80N


Order No.:
02P7025
Manufacturer SKU:
GV4P80N6
Order No.:
02P7026
Manufacturer SKU:
GV4P80S


Order No.:
02P7027
Manufacturer SKU:
GV4PE02N


Order No.:
02P7028
Manufacturer SKU:
GV4PE02N6


Order No.:
02P7029
Manufacturer SKU:
GV4PE02S


Order No.:
02P7031
Manufacturer SKU:
GV4PE03N


Order No.:
02P7032
Manufacturer SKU:
GV4PE03N6


Order No.:
02P7033
Manufacturer SKU:
GV4PE03S
Order No.:
02P7035
Manufacturer SKU:
GV4PE07N
Protect your electric motor effectively with a motor protection switch
The purpose of a motor protection switch (MSS) is to protect electric motors from overload. This can be a form of thermal overload caused by a mechanical overload. But it is also necessary to prevent non-starting or failure of external conductors with the help of a motor protection switch. Monitoring is therefore implemented thermo-mechanically, thermo-electrically or electronically.
Motor-protective circuit breakers are used, for example, with three-phase motors. They always have an overcurrent and a short-circuit current release device, and in some cases also an undervoltage release.
Buy motor protection switches - what to consider?
If you are looking for a suitable motor protection switch, it is important to take a close look at the electric motor to be connected. After all, the choice of the right motor-protective circuit breaker depends on the rated current of the motor. In addition, various standards may have to be observed. For example, if the motor-protective circuit-breaker is to provide overload protection and short-circuit protection for the cable and the motor. In this case, the motor protection switch must be installed at the beginning of the motor allocation in accordance with DIN VDE 0113.
Do you have questions about the motor protection switches in the Bürklin Elektronik online store? Or do you need detailed advice regarding the models shown? Don't hesitate and contact the Bürklin experts via telephone or e-mail! We are here for you and your questions.