Motor Protection Switches
Order No.:
02P6738
Manufacturer SKU:
GV2ME05


Order No.:
02P6751
Manufacturer SKU:
GV2ME073
Order No.:
02P6828
Manufacturer SKU:
GV2P05
Order No.:
02P6830
Manufacturer SKU:
GV2P06


Order No.:
02P6832
Manufacturer SKU:
GV2P07
Order No.:
02P6834
Manufacturer SKU:
GV2P08
Order No.:
02P6836
Manufacturer SKU:
GV2P10
Order No.:
03P4263
Manufacturer SKU:
LRD06
Order No.:
03P4266
Manufacturer SKU:
LRD07


Order No.:
03P4269
Manufacturer SKU:
LRD08


Order No.:
03P4272
Manufacturer SKU:
LRD10


Order No.:
03P5327
Manufacturer SKU:
12429311


Order No.:
03P5328
Manufacturer SKU:
12429312


Order No.:
03P7250
Manufacturer SKU:
12429315


Order No.:
03P7251
Manufacturer SKU:
12429313


Order No.:
03P7252
Manufacturer SKU:
12429368


Order No.:
03P7253
Manufacturer SKU:
12429369


Order No.:
03P7254
Manufacturer SKU:
12429371


Order No.:
03P7259
Manufacturer SKU:
12429317


Order No.:
03P7261
Manufacturer SKU:
12429372
Protect your electric motor effectively with a motor protection switch
The purpose of a motor protection switch (MSS) is to protect electric motors from overload. This can be a form of thermal overload caused by a mechanical overload. But it is also necessary to prevent non-starting or failure of external conductors with the help of a motor protection switch. Monitoring is therefore implemented thermo-mechanically, thermo-electrically or electronically.
Motor-protective circuit breakers are used, for example, with three-phase motors. They always have an overcurrent and a short-circuit current release device, and in some cases also an undervoltage release.
Buy motor protection switches - what to consider?
If you are looking for a suitable motor protection switch, it is important to take a close look at the electric motor to be connected. After all, the choice of the right motor-protective circuit breaker depends on the rated current of the motor. In addition, various standards may have to be observed. For example, if the motor-protective circuit-breaker is to provide overload protection and short-circuit protection for the cable and the motor. In this case, the motor protection switch must be installed at the beginning of the motor allocation in accordance with DIN VDE 0113.
Do you have questions about the motor protection switches in the Bürklin Elektronik online store? Or do you need detailed advice regarding the models shown? Don't hesitate and contact the Bürklin experts via telephone or e-mail! We are here for you and your questions.